Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
Braz. arch. biol. technol ; 63: e20200022, 2020. tab, graf
Article in English | LILACS | ID: biblio-1132196

ABSTRACT

Abstract Despite its potential in the production of polymers from renewable sources, D-limonene faces difficulties in its polymerization, resulting in low monomer conversion and molar mass. In order to investigate the non-ideality inherent kinetics, this work explores different modeling strategies for D-limonene radical polymerization, using benzoyl peroxide as initiator. The starting model considered the classical approach for conventional radical polymerization. This model was then corrected by including reaction orders different from the unit. After an analysis and choice of the best model, computer simulations were compared with experimental results from literature, validating the chosen approach. It was found that the process is drastically influenced by chain transfer reactions, presenting a non-ideal behavior. Finally, an analysis of distinct reaction conditions provided information on monomer conversion, molar mass and polymer dispersity, which could guide future research in the synthesis optimization. Higher molar mass poly(limonene) were obtained by simultaneously reducing the monomer and initiator concentrations.


Subject(s)
Polymers/chemistry , Kinetics , Limonene , Styrene , Polymerization , Chemistry Techniques, Synthetic , Models, Theoretical
2.
Safety and Health at Work ; : 229-236, 2019.
Article in English | WPRIM | ID: wpr-761347

ABSTRACT

BACKGROUND: Emerging reports suggest the potential for adverse health effects from exposure to emissions from some additive manufacturing (AM) processes. There is a paucity of real-world data on emissions from AM machines in industrial workplaces and personal exposures among AM operators. METHODS: Airborne particle and organic chemical emissions and personal exposures were characterized using real-time and time-integrated sampling techniques in four manufacturing facilities using industrial-scale material extrusion and material jetting AM processes. RESULTS: Using a condensation nuclei counter, number-based particle emission rates (ERs) (number/min) from material extrusion AM machines ranged from 4.1×1010 (Ultem filament) to 2.2×1011 [acrylonitrile butadiene styrene and polycarbonate filaments). For these same machines, total volatile organic compound ERs (mg/min) ranged from 1.9×104 (acrylonitrile butadiene styrene and polycarbonate) to 9.4×104 (Ultem). For the material jetting machines, the number-based particle ER was higher when the lid was open (2.3×1010 number/min) than when the lid was closed (1.5–5.5×109 number/min); total volatile organic compound ERs were similar regardless of the lid position. Low levels of acetone, benzene, toluene, and m,p-xylene were common to both AM processes. Carbonyl compounds were detected; however, none were specifically attributed to the AM processes. Personal exposures to metals (aluminum and iron) and eight volatile organic compounds were all below National Institute for Occupational Safety and Health (NIOSH)-recommended exposure levels. CONCLUSION: Industrial-scale AM machines using thermoplastics and resins released particles and organic vapors into workplace air. More research is needed to understand factors influencing real-world industrial-scale AM process emissions and exposures.


Subject(s)
Humans , Acetone , Benzene , Metals , Styrene , Toluene , Volatile Organic Compounds
3.
Safety and Health at Work ; : 103-108, 2019.
Article in English | WPRIM | ID: wpr-761330

ABSTRACT

BACKGROUND: This study was designed to provide logical backgrounds for the revision of biological exposure indices (BEIs) for styrene exposure in Korea. In order to investigate the correlation between airborne styrene and biological exposure indices, we measured urinary mandelic acid (MA) and phenylglyoxylic acid (PGA) in workers exposed to styrene occupationally, as well as airborne styrene at workplaces. METHODS: Surveys were conducted for 56 subjects. The concentrations of airborne styrene and urinary metabolites of styrene were measured in 36 workers who were occupationally exposed to styrene, and in 20 controls. Air samples were collected using personal air samplers and analyzed by gas chromatography. Urine samples were collected at the end of the shift and analyzed by high performance liquid chromatography. RESULTS: The geometric mean concentration of airborne styrene was 9.6 ppm. The concentrations of urinary MA, PGA, and MA+PGA in the exposure group were 267.7, 143.3, and 416.8 mg/g creatinine, respectively. The correlation coefficients for correlation between airborne styrene and MA, PGA, and MA+PGA were 0.714, 0.604, and 0.769, respectively. The sum of urinary MA and PGA corresponding to an exposure of 20 ppm styrene was 603 mg/g creatinine. CONCLUSION: The correlation of the sum of urinary MA and PGA with airborne styrene was better than the correlation of each individual urinary determinant. It is considered appropriate to amend the concentration of urinary MA+PGA to 600 mg/g creatinine as a BEI, which corresponds to an airborne styrene concentration of 20 ppm in Korea.


Subject(s)
Humans , Chromatography, Gas , Chromatography, Liquid , Creatinine , Korea , Logic , Occupations , Styrene
4.
Environmental Health and Toxicology ; : 2018007-2018.
Article in English | WPRIM | ID: wpr-786748

ABSTRACT

The industrial complexes built during the course of economic development in South Korea played a pivotal role in the country's rapid economic growth. However, this growth was accompanied by health problems due to the pollutants released from the industrial complexes inevitably located near residential areas, given the limited land area available in South Korea. This study was conducted to evaluate the exposure to each pollutant emanating from industrial complexes for residents living in nearby areas, and to determine the substances requiring priority attention in future surveys. Pollutants were comprehensively categorized according to their emission and exposure levels based on data previously collected from the study areas. The emission, ambient concentration, and biomarker concentration levels of major pollutants emitted from eight national industrial complexes (Ulsan, Pohang, Gwangyang, Yeosu, Chungju, Daesan, Sihwa, and Banwol) were determined and tabulated. Each of the values was compared with the national/local average values, reference values, or control area concentrations depending on availability. Substances with completed exposure pathways and with high values for emissions, ambient concentrations, and biomarker concentrations were considered the substances posing exposure risks to the residents living near the corresponding industrial complex. The substances requiring continuous monitoring or supplementary exposure investigation were also categorized and presented. Lead and benzene had higher values for emissions, ambient concentrations, and biomarker concentrations in the Ulsan Industrial Complex area; thus, they were most likely to pose exposure risks to residents living in the area's neighborhoods. In other areas, styrene, xylene, cadmium, nitrogen oxide, trichloroethylene, nickel, manganese, and chromium required continuous monitoring, and arsenic, nickel, manganese, and chromium required biomarker measurements. In conclusion, the substances identified and categorized in this study need to be given appropriate attention in future surveys on exposure risks and health effects related to industrial complexes.


Subject(s)
Arsenic , Benzene , Cadmium , Chromium , Economic Development , Environmental Pollutants , Korea , Manganese , Nickel , Nitrogen , Reference Values , Residence Characteristics , Styrene , Trichloroethylene , Xylenes
5.
Environmental Health and Toxicology ; : e2018007-2018.
Article in English | WPRIM | ID: wpr-714899

ABSTRACT

The industrial complexes built during the course of economic development in South Korea played a pivotal role in the country's rapid economic growth. However, this growth was accompanied by health problems due to the pollutants released from the industrial complexes inevitably located near residential areas, given the limited land area available in South Korea. This study was conducted to evaluate the exposure to each pollutant emanating from industrial complexes for residents living in nearby areas, and to determine the substances requiring priority attention in future surveys. Pollutants were comprehensively categorized according to their emission and exposure levels based on data previously collected from the study areas. The emission, ambient concentration, and biomarker concentration levels of major pollutants emitted from eight national industrial complexes (Ulsan, Pohang, Gwangyang, Yeosu, Chungju, Daesan, Sihwa, and Banwol) were determined and tabulated. Each of the values was compared with the national/local average values, reference values, or control area concentrations depending on availability. Substances with completed exposure pathways and with high values for emissions, ambient concentrations, and biomarker concentrations were considered the substances posing exposure risks to the residents living near the corresponding industrial complex. The substances requiring continuous monitoring or supplementary exposure investigation were also categorized and presented. Lead and benzene had higher values for emissions, ambient concentrations, and biomarker concentrations in the Ulsan Industrial Complex area; thus, they were most likely to pose exposure risks to residents living in the area's neighborhoods. In other areas, styrene, xylene, cadmium, nitrogen oxide, trichloroethylene, nickel, manganese, and chromium required continuous monitoring, and arsenic, nickel, manganese, and chromium required biomarker measurements. In conclusion, the substances identified and categorized in this study need to be given appropriate attention in future surveys on exposure risks and health effects related to industrial complexes.


Subject(s)
Arsenic , Benzene , Cadmium , Chromium , Economic Development , Environmental Pollutants , Korea , Manganese , Nickel , Nitrogen , Reference Values , Residence Characteristics , Styrene , Trichloroethylene , Xylenes
6.
Environmental Health and Toxicology ; : 2017006-2017.
Article in English | WPRIM | ID: wpr-786733

ABSTRACT

This study was conducted to evaluate the ability of plants to purify indoor air by observing the effective reduction rate among pollutant types of particulate matter (PM) and volatile organic compounds (VOCs). PM and four types of VOCs were measured in a new building that is less than three years old and under three different conditions: before applying the plant, after applying the plant, and a room without a plant. The removal rate of each pollutant type due to the plant was also compared and analyzed. In the case of indoor PM, the removal effect was negligible because of outdoor influence. However, 9% of benzene, 75% of ethylbenzene, 72% of xylene, 75% of styrene, 50% of formaldehyde, 36% of acetaldehyde, 35% of acrolein with acetone, and 85% of toluene were reduced. The purification of indoor air by natural ventilation is meaningless because the ambient PM concentration has recently been high. However, contamination by gaseous materials such as VOCs can effectively be removed through the application of plants.


Subject(s)
Acetaldehyde , Acetone , Acrolein , Benzene , Formaldehyde , Particulate Matter , Plants , Styrene , Toluene , Ventilation , Volatile Organic Compounds , Xylenes
7.
Safety and Health at Work ; : 329-336, 2017.
Article in English | WPRIM | ID: wpr-17177

ABSTRACT

A review study was conducted to examine the adverse effects of styrene, styrene mixtures, or styrene and/or styrene mixtures and noise on the auditory system in humans employed in occupational settings. The search included peer-reviewed articles published in English language involving human volunteers spanning a 25-year period (1990–2015). Studies included peer review journals, case–control studies, and case reports. Animal studies were excluded. An initial search identified 40 studies. After screening for inclusion, 13 studies were retrieved for full journal detail examination and review. As a whole, the results range from no to mild associations between styrene exposure and auditory dysfunction, noting relatively small sample sizes. However, four studies investigating styrene with other organic solvent mixtures and noise suggested combined exposures to both styrene organic solvent mixtures may be more ototoxic than exposure to noise alone. There is little literature examining the effect of styrene on auditory functioning in humans. Nonetheless, findings suggest public health professionals and policy makers should be made aware of the future research needs pertaining to hearing impairment and ototoxicity from styrene. It is recommended that chronic styrene-exposed individuals be routinely evaluated with a comprehensive audiological test battery to detect early signs of auditory dysfunction.


Subject(s)
Adult , Animals , Humans , Administrative Personnel , Healthy Volunteers , Hearing Loss , Mass Screening , Noise , Peer Review , Public Health , Sample Size , Styrene
8.
Environmental Health and Toxicology ; : e2017006-2017.
Article in English | WPRIM | ID: wpr-203751

ABSTRACT

This study was conducted to evaluate the ability of plants to purify indoor air by observing the effective reduction rate among pollutant types of particulate matter (PM) and volatile organic compounds (VOCs). PM and four types of VOCs were measured in a new building that is less than three years old and under three different conditions: before applying the plant, after applying the plant, and a room without a plant. The removal rate of each pollutant type due to the plant was also compared and analyzed. In the case of indoor PM, the removal effect was negligible because of outdoor influence. However, 9% of benzene, 75% of ethylbenzene, 72% of xylene, 75% of styrene, 50% of formaldehyde, 36% of acetaldehyde, 35% of acrolein with acetone, and 85% of toluene were reduced. The purification of indoor air by natural ventilation is meaningless because the ambient PM concentration has recently been high. However, contamination by gaseous materials such as VOCs can effectively be removed through the application of plants.


Subject(s)
Acetaldehyde , Acetone , Acrolein , Benzene , Formaldehyde , Particulate Matter , Plants , Styrene , Toluene , Ventilation , Volatile Organic Compounds , Xylenes
10.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 301-303, 2015.
Article in Chinese | WPRIM | ID: wpr-326002

ABSTRACT

<p><b>OBJECTIVE</b>To develop a method for determination of mandelic acid (MA) and phenylglyoxylic acid (PGA) in urine by reagent-free ion chromatography.</p><p><b>METHODS</b>Ion chromatography was performed on an AS19 column with a gradient elution solution containing 10-35 mmoL/L KOH at a flow rate of 1.00 ml/min, and MA and PGA were detected at ultraviolet wavelengths of 225 nm and 254 nm, respectively. The samples were diluted 10 times with purified water, then purified on a silver column to remove high concentrations of chloride ion, and injected after being filtered through a 0.2-µm m filter membrane.</p><p><b>RESULTS</b>The recoveries of standard addition of MA and PGA were 96.5% and 99.3%, respectively, with both relative standard deviations less than 5.0%. Good linear relationships were noted in the range of 1.0-100.0 mg/L for both MA and PGA (r >0.9995). The detection limits of MA and PGA were 0.02 mg/L and 0.05 mg/L, respectively; the minimum detectable concentrations of MA and PGA were 0.2 mg/L and 0.5 mg/L (when the sampling amount was 5.0 ml and diluted to 50.0 ml with water, and the injection volume was 300 µL).</p><p><b>CONCLUSIONS</b>This method is fast, convenient, and highly sensitive and selective. It can be used for the analysis of MA and PGA in the urine of styrene-exposed workers.</p>


Subject(s)
Humans , Chromatography, Ion Exchange , Glyoxylates , Urine , Mandelic Acids , Urine , Styrene
11.
Salud pública Méx ; 56(6): 579-591, nov.-dic. 2014. ilus, tab
Article in English | LILACS | ID: lil-733352

ABSTRACT

Objective. To conduct a health impact assessment (HIA) to quantify health benefits for several PM and O3 air pollution reduction scenarios in the Mexico City Metropolitan Area (MCMA). Results from this HIA will contribute to the scientific support of the MCMA air quality management plan (PROAIRE) for the period 2011-2020. Materials and methods. The HIA methodology consisted of four steps: 1) selection of the air pollution reduction scenarios, 2) identification of the at-risk population and health outcomes for the 2005 baseline scenario, 3) selection of concentration-response functions and 4) estimation of health impacts. Results. Reductions of PM10 levels to 20 μg/m³ and O3 levels to 0.050ppm (98 µg/m³) would prevent 2300 and 400 annual deaths respectively. The greatest health impact was seen in the over-65 age group and in mortality due to cardiopulmonary and cardiovascular disease. Conclusion. Improved air quality in the MCMA could provide significant health benefits through focusing interventions by exposure zones.


Objetivo. Realizar una evaluación de impacto en salud (EIS) que documente los beneficios en salud ante diversos escenarios de reducción de PM10 y O3 en el aire de la Zona Metropolitana del Valle de México (ZMVM). Los resultados contribuyen al sustento científico del plan de gestión de calidad del aire (PROAIRE 2011-2020). Material y métodos. La metodología de EIS comprende cuatro pasos: 1) selección de los escenarios de reducción, 2) identificación de la población en riesgo y de los eventos en salud para el año basal 2005, 3) selección de las funciones de concentración-respuesta y 4) estimación del impacto en la salud. Resultados. Reducciones de PM10 a 20μg/m³ y de O3 a 0.050ppm (98 µg/m³) evitarían, respectivamente, cerca de 2 300 y 400 muertes por año. El mayor impacto se observa en el grupo de más de 65 años y en la mortalidad por causas cardiopulmonares y cardiovasculares. Conclusiones. Mejorar la calidad del aire en la ZMVM podría reflejar importantes beneficios para la salud focalizados por zonas o áreas de exposición.


Subject(s)
Pseudomonas putida/metabolism , Styrenes/metabolism , Aldehyde Oxidoreductases/metabolism , Biodegradation, Environmental , Epoxy Compounds/metabolism , Escherichia coli Proteins , Glutamic Acid/metabolism , Isomerases/metabolism , Oxidation-Reduction , Oxygen Consumption , Phenylacetates/metabolism , Pseudomonas putida/enzymology , Pseudomonas putida/growth & development , Styrene , Succinates/metabolism , Succinic Acid
12.
Allergy, Asthma & Immunology Research ; : 517-524, 2014.
Article in English | WPRIM | ID: wpr-197334

ABSTRACT

PURPOSE: This study was aimed to investigate the relationship between indoor air pollutant levels and residential environment in children with atopic dermatitis (AD) living in Seoul. METHODS: A total of 150 children with AD were included. Residential environment was assessed by questionnaires which were completed by their parents. To evaluate the level of exposure to the indoor air pollutants, concentrations of the indoor air pollutants including particulate matter with diameter less than 10 microm (PM10), formaldehyde, carbon dioxide (CO2), carbon monoxide (CO), nitrogen dioxide (NO2), Total Volatile Organic Compound (TVOC), benzene, toluene, ethyl-benzene, xylene, styrene, bacterial aerosols, and airborne fungi were measured. RESULTS: A significant difference was exhibited in the levels of PM10 in case of visible fungus on the walls (P=0.047). There was relationship between the construction year of the house, moving to a newly constructed building within 1 year and formaldehyde level. With the use of artificial air freshener, the differences were found in the concentrations of TVOC (P=0.003), benzene (P=0.015), toluene (P=0.012) and ethyl-benzene (P=0.027). The concentration of xylene was significantly high when oil was used as heating fuel (P=0.015). Styrene exhibited differences depending on building type and its concentrations were significantly high in a residential and commercial complex building (P=0.005). The indoor concentration of bacterial aerosols was significantly low with the use of air cleaner (P=0.045). High NO2, benzene concentrations were present in case of almost no ventilation (P=0.028 and P=0.028, respectively). CONCLUSIONS: Individual residential environments are closely related with the levels of the indoor air pollutants. To alleviate AD symptoms, simple questions about residential environments such as visible fungus on the walls and the use of artificial air freshener are helpful to assess the possibility of increased indoor air pollutant levels when direct measurement is not available.


Subject(s)
Child , Humans , Aerosols , Air Pollutants , Air Pollution , Benzene , Carbon Dioxide , Carbon Monoxide , Dermatitis, Atopic , Formaldehyde , Fungi , Heating , Hot Temperature , Nitrogen Dioxide , Parents , Particulate Matter , Seoul , Styrene , Toluene , Ventilation , Xylenes , Surveys and Questionnaires
13.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 830-833, 2013.
Article in Chinese | WPRIM | ID: wpr-275805

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the relationship between genetic polymorphisms of glutathione S-transferase P1 (GSTP1), glutathione S-transferase M1 (GSTM1), and glutathione S-transferase T1 (GSTT1) and urinary level of mercapturic acids of styrene (PHEMAs) in workers exposed to styrene.</p><p><b>METHODS</b>One hundred and twenty-six workers exposed to styrene were selected as exposure group, and 150 workers without styrene exposure as the control group; all the workers came from a locomotive shell production factory in Shandong Province, China. The PCR-RFLP technique was applied to analyze the individual genetic polymorphisms of GSTP1; the multiplex PCR technique was used to investigate the genetic polymorphisms of GSTM1 and GSTT1; the relationship between genetic polymorphisms of GSTP1, GSTM1, and GSTT1 and urinary level of PHEMAs in workers exposed to styrene was statistically analyzed.</p><p><b>RESULTS</b>The three genotypes investigated in the study had a distribution in accordance with the Chinese population. With exposure to high- concentration styrene, the individuals carrying GSTP1 (exon5, A105G) AA genotype (wildtype) had a significantly higher urinary level of PHEMAs (43.58 mg/g) than those with mutant genotypes AG (29.769 mg/g) and GG (30.245 mg/g); the urinary level of PHEMAs in individuals carrying wild-type GSTM1 genotype was significantly higher than that in individuals carrying deficient-type GSTM1 genotype (40.197 mg/g vs 28.866 mg/g, P < 0.05); no significant difference in urinary level of PHEMAs was found between individuals carrying wild-type GSTT1 genotype and deficient-type GSTT1 genotype. There was no significant relationship between the three gene polymorphisms and urinary level of PHEMAs in the control group.</p><p><b>CONCLUSION</b>The genetic polymorphisms of GSTP1 and GSTM1 may be related to urinary level of PHEMAs in workers exposed to styrene.</p>


Subject(s)
Adult , Female , Humans , Male , Young Adult , Acetylcysteine , Urine , Genotype , Glutathione S-Transferase pi , Genetics , Glutathione Transferase , Genetics , Occupational Exposure , Polymorphism, Genetic , Styrene , Urine
14.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 496-499, 2013.
Article in Chinese | WPRIM | ID: wpr-343621

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the role of genetic polymorphisms of epoxide hydrolase 1 (EPHX1) in the metabolism of styrene in vivo.</p><p><b>METHODS</b>Fifty-six styrene-exposed workers, who worked in the painting workshop of an enterprise for manufacturing glass fiber-reinforced plastic yachts in Shandong Province, China for over one year and were protected in approximately the same way, were selected as study subjects. The 8-hour time-weighted average concentration (8 h-TWA) of styrene and the concentrations of mandelic acid (MA) and phenyl glyoxylic acid (PGA) as urinary metabolites were measured. The genetic polymorphisms of EPHX1 were detected by polymerase chain reaction-restriction fragment length polymorphism analysis.</p><p><b>RESULTS</b>The urinary concentrations of MA and PGA were 177.25±82.36 mg/g Cr and 145.91±69.73 mg/g Cr, respectively, and the 8 h-TWA of styrene was 133.28±95.81 mg/m3. Urinary concentrations of MA and PGA were positively correlated with 8 h-TWA of styrene (R=0.861, P < 0.05; R=0.868, P < 0.05). The subjects were divided into high-exposure group (8 h-TWA >50 mg/m(3)) and low-exposure group (8 h-TWA ≤ 50 mg/m(3), and in the two groups, the urinary concentrations of MA and PGA were significantly higher in the individuals carrying high-activity genotypes of EPHX1 than in those carrying low-activity genotypes of EPHX1 (P < 0.05).</p><p><b>CONCLUSION</b>Genetic polymorphisms of EPHX1 play an important role in the metabolic process of styrene in vivo.</p>


Subject(s)
Adult , Humans , Male , Air Pollutants, Occupational , Pharmacokinetics , China , Epoxide Hydrolases , Genetics , Glyoxylates , Urine , Mandelic Acids , Urine , Occupational Exposure , Polymorphism, Genetic , Styrene , Pharmacokinetics
15.
Annals of Occupational and Environmental Medicine ; : 25-2013.
Article in English | WPRIM | ID: wpr-84428

ABSTRACT

OBJECTIVES: We report a case of death due to asthma attack in a plastic injection process worker with a history of asthma. METHODS: To assess task relevance, personal history including occupational history and medical records were reviewed. Samples of the substances utilized in the injection process were collected by visiting the patient's workplace. The work environment with the actual process was reproduced in the laboratory, and the released substances were evaluated. RESULTS: The medical records confirmed that the patient's conventional asthma was in remission. The analysis of the resins discharged from the injection process simulation revealed styrene, which causes occupational asthma, and benzenepropanoic acid, 3,5-bis(1,1-dimethylethyl)-4-hydroxy-, and octadecyl ester. Even though it was not the case in the present study, various harmful substances capable of inducing asthma such as formaldehyde, acrolein, and acetic acid are released during resin processing. CONCLUSION: A worker was likely to occur occupational asthma as a result of the exposure to the harmful substances generated during the plastic injection process.


Subject(s)
Humans , Acetic Acid , Acrolein , Asthma , Asthma, Occupational , Formaldehyde , Medical Records , Plastics , Styrene
16.
Safety and Health at Work ; : 58-66, 2012.
Article in English | WPRIM | ID: wpr-182038

ABSTRACT

OBJECTIVES: The purpose of this study was to review clinical characteristics and working environments of sudden cardiac death (SCD) cases associated with a tire manufacturer in Korea, and review possible occupational risk factors for cardiovascular disease including nanoparticles (ultrafine particles, UFPs). METHODS: We reviewed (i) the clinical course of SCD cases and (ii) occupational and non-occupational risk factors including chemicals, the physical work environment, and job characteristics. RESULTS: Possible occupational factors were chemicals, UFPs of rubber fume, a hot environment, shift work, overworking, and noise exposure. The mean diameter of rubber fume (63-73 nm) was (larger than diesel exhaust [12 nm] and outdoor dust [50 nm]). The concentration of carbon disulfide, carbon monoxide and styrene were lower than the limit of detection. Five SCD cases were exposed to shift work and overworking. Most of the cases had several non-occupational factors such as hypertension, overweight and smoking. CONCLUSION: The diameter of rubber fume was larger than outdoor and the diesel exhaust, the most well known particulate having a causal relationship with cardiovascular disease. The possibility of a causal relation between UFPs of rubber fume and SCD was not supported in this study. However, it is necessary to continue studying the relationship between large sized UFPs and SCD.


Subject(s)
Carbon Disulfide , Carbon Monoxide , Cardiovascular Diseases , Death, Sudden, Cardiac , Dust , Heart Arrest , Heat Stress Disorders , Hypertension , Korea , Limit of Detection , Nanoparticles , Noise , Overweight , Risk Factors , Rubber , Styrene , Vehicle Emissions
17.
Environmental Health and Toxicology ; : e2012012-2012.
Article in English | WPRIM | ID: wpr-118827

ABSTRACT

OBJECTIVES: The aim of this study was to identify the health and environmental risk factors of air contaminants that influence environmental and respiratory diseases in Gyeongju, Pohang and Ulsan in South Korea, with a focus on volatile organic compounds (VOCs). METHODS: Samples were collected by instantaneous negative pressure by opening the injection valve in the canister at a fixed height of 1 to 1.5 m. The sample that was condensed in -150degrees C was heated to 180degrees C in sample pre-concentration trap using a 6-port switching valve and it was injected to a gas chromatography column. The injection quantity of samples was precisely controlled using an electronic flow controller equipped in the gas chromatography-mass spectrometer. RESULTS: The quantity of the VOC emissions in the industrial area was 1.5 to 2 times higher than that in the non-industrial area. With regards to the aromatic hydrocarbons, toluene was detected at the highest level of 22.01 ppb in Ulsan, and chloroform was the halogenated hydrocarbons with the highest level of 10.19 ppb in Pohang. The emission of toluene was shown to be very important, as it accounted for more than 30% of the total aromatic hydrocarbon concentration. CONCLUSIONS: It was considered that benzene in terms of the cancer-causing grade standard, toluene in terms of the emission quantity, and chloroform and styrene in terms of their grades and emission quantities should be selected for priority measurement substances.


Subject(s)
Benzene , Chloroform , Chromatography, Gas , Electronics , Electrons , Hot Temperature , Hydrocarbons, Aromatic , Hydrocarbons, Halogenated , Republic of Korea , Risk Factors , Styrene , Toluene , Volatile Organic Compounds
18.
Safety and Health at Work ; : 130-139, 2012.
Article in English | WPRIM | ID: wpr-8702

ABSTRACT

OBJECTIVES: The purpose of this study is to evaluate the tire manufacturing work environments extensively and to identify workers' exposure to hazardous substances in various work processes. METHODS: Personal air sampling was conducted to measure polycyclic aromatic hydrocarbons, carbon disulfide, 1,3-butadiene, styrene, methyl isobutyl ketone, methylcyclohexane, formaldehyde, sulfur dioxide, and rubber fume in tire manufacturing plants using the National Institute for Occupational Safety Health Manual of Analytical Methods. Noise, carbon monoxide, and heat stress exposure were evaluated using direct reading instruments. Past concentrations of rubber fume were assessed using regression analysis of total particulate data from 2003 to 2007, after identifying the correlation between the concentration of total particulate and rubber fume. RESULTS: Workers were exposed to rubber fume that exceeded 0.6 mg/m3, the maximum exposure limit of the UK, in curing and production management processes. Forty-seven percent of workers were exposed to noise levels exceeding 85 dBA. Workers in the production management process were exposed to 28.1degrees C (wet bulb globe temperature value, WBGT value) even when the outdoor atmosphere was 2.7degrees C (WBGT value). Exposures to other substances were below the limit of detection or under a tenth of the threshold limit values given by the American Conference of Governmental Industrial Hygienists. CONCLUSION: To better classify exposure groups and to improve work environments, examining closely at rubber fume components and temperature as risk indicators in tire manufacturing is recommended.


Subject(s)
Humans , Aerosols , Atmosphere , Butadienes , Carbon Disulfide , Carbon Monoxide , Cyclohexanes , Formaldehyde , Hazardous Substances , Hot Temperature , Limit of Detection , Methyl n-Butyl Ketone , Noise , Occupational Exposure , Occupational Health , Polycyclic Aromatic Hydrocarbons , Rubber , Styrene , Sulfur Dioxide , Threshold Limit Values
19.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery ; (24): 176-179, 2011.
Article in Chinese | WPRIM | ID: wpr-748502

ABSTRACT

OBJECTIVE@#To observe the effects of N-acetyl-L-cysteine (L-NAC) protect hair cells in the rat cochlea from injury of exposure to styrene.@*METHOD@#Seventeen adult Long Evans rats were used in present study. The animals were randomly assigned into test group (n=9) and control group (n=8). The animals were exposed to styrene by gavage at 400 mg/kg (2 g styrene was mixed with 1 ml olive oil). Test group animals received styrene exposure plus L-NAC 325 mg/kg (L-NAC was dissolved in physiological saline solution) by intraperitoneal injection. Treatment was performed once a day, 5 days per week for 3 weeks. Control group animals received the same volume of saline injection on an identical time schedule used for the test group. The auditory brainstem response (ABR) thresholds of both ears elicited with clicks were measured before and at the end of the 3-week styrene or styrene plus L-NAC treatment. After hearing was re-assessed, animals were sacrificed and cochleae were quickly removed from the skull. Following fixation, whole specimens comprising the basilar membrane with Corti's organ were separated from the modiolus. The organs of Corti were stained with propidium iodide (PI) and the TUNEL assay to visualize the morphologic viability of hair cell nuclei, FITC-labeled phalloidin, a F-actin intercalating fluorescent probe used to visualize the morphologic viability of cuticular plate and the stereocilia in the hair cells. Each organ of Corti was thoroughly examined using fluorescence microscopy. The numbers of damaged OHCs (apoptotic, necrotic and missing OHCs) were documented.@*RESULT@#There was a statistically significant decrease in ABR threshold shift (P0.05).@*CONCLUSION@#The results indicate that the treatment with L-NAC may effectively protect against the styrene-induced hair cells damage and preferably reduce the number of apoptotic OHCs.


Subject(s)
Animals , Rats , Acetylcysteine , Pharmacology , Antioxidants , Pharmacology , Cochlea , Cell Biology , Evoked Potentials, Auditory, Brain Stem , Hair Cells, Auditory , Pathology , Lysine , Pharmacology , Rats, Long-Evans , Styrene
20.
Iranian Journal of Environmental Health Science and Engineering. 2011; 8 (2): 159-168
in English | IMEMR | ID: emr-109491

ABSTRACT

Considering concurrent use of styrene and acrylonitrile as raw materials in the production of synthetic resins and plastic and their associated differences in physiochemical properties and biodegradability, our experiments were conducted in a three-stage downflow bench-scale biofilter to study the potential suppressive effects of acrylonitrile on styrene removal. A Mixture of yard waste compost and shredded plastics and activated sludge was used as bed media. Gas phase concentration of styrene and acrylonitrile was determined via gas chromatographic analysis. Under steady-state conditions, maximum elimination capacity of styrene and acrylonitrile was 44 and 120 g/m[3] h, respectively. The effect of moisture was very significant in reducing the specific adsorptive capacity [microg/g of bed media] of styrene and acrylonitrile. The bed media with 60% moisture content lost styrene absorption capacities by more than one order of magnitude when compared to dry media. The existence of water increased the absorption capacity of medium for acrylonitrile about 95%. Styrene elimination capacity of the biofilter during co-treatment was less as compared to pure styrene biodegradation indicating the likelihood of inhibitory kinetics. Introduction of acrylonitrile into the air stream reduced elimination capacity of styrene to 103 g/m[3] h. The adverse impact on removal rate of acrylonitrile due to the presence of styrene in the gas stream was minimal. Carbonequivalent removal for the system amounted to about 85 g C/m[3] h at empty bed retention time of 120 s


Subject(s)
Volatilization , Styrene , Gases , Sewage , Chromatography, Gas , Biodegradation, Environmental , Soil
SELECTION OF CITATIONS
SEARCH DETAIL